Finish schedule and spec sheet
Build the finish schedule for your drawing set, room by room. The adhesive class and minimum slip rating fill in for you, and anything that doesn't suit its area is flagged.
How the checks work
Rules used
| What | Rule | Based on |
|---|---|---|
| Adhesive class | Ceramic up to 300 x 300 indoors: Type 1 (C1). Vitrified, porcelain or larger than 300 x 300: Type 2 (C2). Larger than 600 x 600, 1200 mm or longer, external, or tile on tile: Type 4 S1 (C2TE S1). Walls add T (non-slip on vertical surfaces). | IS 15477; EN 12004; Sika selection guide |
| Minimum slip rating | Living and bedrooms R9; kitchen R10; bathroom floor R10 (barefoot B); shower floor R11 (B); balcony and utility R11; external and ramps R12; pool deck R11 (C). | DIN 51130 / DIN 51097 tables; Indian anti-slip guidance; NBC 2016 asks for slip-resistant floors in wet areas and ramps |
| Wear (PEI) | Floors in homes: PEI III or higher. Commercial floors: IV to V. | PEI abrasion classes |
| Ceilings and paint | Bathrooms and kitchens: moisture-resistant (MR) gypsum board and an anti-fungal emulsion. Plan an access panel under valves, geysers and exhaust ducts. | Gypsum board and paint makers' guidance |
| Water absorption | IS 15622 / ISO 13006 groups: BIa up to 0.5% (vitrified), BIb 0.5 to 3%, BIIa 3 to 6%, BIIb 6 to 10%, BIII above 10% (wall tiles only). External and wet floors: BIa or BIb. | IS 15622 |
Come and see it in person
BaFlo Luxe1st Floor, Narada Gana Sabha
254/314, TTK Road, CIT Colony, Alwarpet
Chennai, Tamil Nadu 600018
We're on the 1st floor of Narada Gana Sabha, TTK Road, Alwarpet. Take the stairs or the lift up from the main entrance.
- Open
- Monday to Saturday, 10 am to 7 pm
- Phone
- 098408 44006
- 098408 44006
Visited us? Review us on Google